Welcome to the IKCEST

Prehospital emergency care : official journal of the National Association of EMS Physicians and the National Association of State EMS Directors | Vol.11, Issue.4 | | Pages 467-72

Prehospital emergency care : official journal of the National Association of EMS Physicians and the National Association of State EMS Directors

IO versus IV access while wearing personal protective equipment in a HazMat scenario.

Joe, Suyama Christian C, Knutsen William E, Northington Michael, Hahn David, Hostler  
Abstract

Determine the time difference obtaining intraosseous (IO) versus intravenous (IV) access while wearing personal protective equipment (PPE) in simulated HazMat scenarios.Twenty-two EMT-P providers established anterior tibial IO access using the EZ-IO system and routine antecubital IV access in three mannequin and PPE HazMat scenarios: 1) provider and mannequin not in PPE, 2) only provider in Level C PPE, and 3) provider and mannequin both wearing Level C PPE. Primary outcome measures were the average time in seconds for skin access, vascular access, and fluid infusion with each method in these configurations.For the provider and mannequin not in PPE condition, needle to skin time favored the IV (6.2 vs. 9.3 seconds; p < 0.001). whereas vascular access time (12.8 vs. 36.3 seconds; p < 0.001) and fluid infusion time (26.2 vs. 36.5 seconds; p = 0.02) favored the IO approach. For the provider in PPE and mannequin not in PPE condition, needle to skin times were similar for IO and IV (10.4 vs. 12.7 seconds; p = 0.591), whereas vascular access time (14.0 vs. 46.0 seconds; p < 0.001) and fluid infusion time (28.3 vs. 45.7 seconds; p < 0.001) both favored the IO approach. With the provider and mannequin in PPE, needle to skin time (12.7 vs. 24.9 seconds; p < 0.001), vascular access time (16.9 vs. 62.7 seconds; p < 0.001), and fluid infusion time (29.5 vs. 66.1 seconds; p < 0.001) all favored the IO approach. Fluid infusion times for the provider not in and in PPE (26.2 vs. 28.3 seconds; p < 0.05) with the mannequin not in PPE revealed no significant time burden associated with using the EZ-IO device with the provider in PPE.Overall, the EZ-IO system under HazMat conditions provides vascular access and fluid more quickly than standard intravenous access. When providers and mannequins were both in PPE, the time differential between IO and IV access was the greatest, favoring the IO approach. Donning PPE did not hinder the providers' use of the EZ-IO device and may be useful for obtaining vascular access when wearing PPE.

Original Text (This is the original text for your reference.)

IO versus IV access while wearing personal protective equipment in a HazMat scenario.

Determine the time difference obtaining intraosseous (IO) versus intravenous (IV) access while wearing personal protective equipment (PPE) in simulated HazMat scenarios.Twenty-two EMT-P providers established anterior tibial IO access using the EZ-IO system and routine antecubital IV access in three mannequin and PPE HazMat scenarios: 1) provider and mannequin not in PPE, 2) only provider in Level C PPE, and 3) provider and mannequin both wearing Level C PPE. Primary outcome measures were the average time in seconds for skin access, vascular access, and fluid infusion with each method in these configurations.For the provider and mannequin not in PPE condition, needle to skin time favored the IV (6.2 vs. 9.3 seconds; p < 0.001). whereas vascular access time (12.8 vs. 36.3 seconds; p < 0.001) and fluid infusion time (26.2 vs. 36.5 seconds; p = 0.02) favored the IO approach. For the provider in PPE and mannequin not in PPE condition, needle to skin times were similar for IO and IV (10.4 vs. 12.7 seconds; p = 0.591), whereas vascular access time (14.0 vs. 46.0 seconds; p < 0.001) and fluid infusion time (28.3 vs. 45.7 seconds; p < 0.001) both favored the IO approach. With the provider and mannequin in PPE, needle to skin time (12.7 vs. 24.9 seconds; p < 0.001), vascular access time (16.9 vs. 62.7 seconds; p < 0.001), and fluid infusion time (29.5 vs. 66.1 seconds; p < 0.001) all favored the IO approach. Fluid infusion times for the provider not in and in PPE (26.2 vs. 28.3 seconds; p < 0.05) with the mannequin not in PPE revealed no significant time burden associated with using the EZ-IO device with the provider in PPE.Overall, the EZ-IO system under HazMat conditions provides vascular access and fluid more quickly than standard intravenous access. When providers and mannequins were both in PPE, the time differential between IO and IV access was the greatest, favoring the IO approach. Donning PPE did not hinder the providers' use of the EZ-IO device and may be useful for obtaining vascular access when wearing PPE.

+More

Cite this article
APA

APA

MLA

Chicago

Joe, Suyama Christian C, Knutsen William E, Northington Michael, Hahn David, Hostler,.IO versus IV access while wearing personal protective equipment in a HazMat scenario.. 11 (4),467-72.

Disclaimer: The translated content is provided by third-party translation service providers, and IKCEST shall not assume any responsibility for the accuracy and legality of the content.
Translate engine
Article's language
English
中文
Pусск
Français
Español
العربية
Português
Kikongo
Dutch
kiswahili
هَوُسَ
IsiZulu
Action
Recommended articles

Report

Select your report category*



Reason*



By pressing send, your feedback will be used to improve IKCEST. Your privacy will be protected.

Submit
Cancel