Influence of Torso Model Complexity on the Noninvasive Localization of Ectopic Ventricular Activity

  
Abstract

Location of premature ectopic ventricular activity was assessed noninvasively in five patients using integral body surface potential maps and inverse solution in terms of a single dipole. Precision of the inverse solution was studied using three different torso models: homogeneous torso model, inhomogeneous torso model including lungs and heart ventricles and inhomogeneous torso model including lungs, heart ventricles and atria, aorta and pulmonary artery. More stable results were obtained using the homogeneous model. However, in some patients the location of the resulting dipole representing the focus of ectopic activity was shifted between solutions using the homogeneous and inhomogeneous models. Comparison of solutions with inhomogeneous torso models did not show significantly different dispersions, but localization of the focus was better when a torso model including atria and arteries was used. The obtained results suggest that presented noninvasive localization of the ectopic focus can be used to shorten the time needed for successful ablation and to increase its success rate.

Original Text (This is the original text for your reference.)

Influence of Torso Model Complexity on the Noninvasive Localization of Ectopic Ventricular Activity

Location of premature ectopic ventricular activity was assessed noninvasively in five patients using integral body surface potential maps and inverse solution in terms of a single dipole. Precision of the inverse solution was studied using three different torso models: homogeneous torso model, inhomogeneous torso model including lungs and heart ventricles and inhomogeneous torso model including lungs, heart ventricles and atria, aorta and pulmonary artery. More stable results were obtained using the homogeneous model. However, in some patients the location of the resulting dipole representing the focus of ectopic activity was shifted between solutions using the homogeneous and inhomogeneous models. Comparison of solutions with inhomogeneous torso models did not show significantly different dispersions, but localization of the focus was better when a torso model including atria and arteries was used. The obtained results suggest that presented noninvasive localization of the ectopic focus can be used to shorten the time needed for successful ablation and to increase its success rate.

+More

Cite this article
APA

APA

MLA

Chicago

,.Influence of Torso Model Complexity on the Noninvasive Localization of Ectopic Ventricular Activity. 16 (2),.

References

Disclaimer: The translated content is provided by third-party translation service providers, and IKCEST shall not assume any responsibility for the accuracy and legality of the content.
Translate engine
Article's language
English
中文
Pусск
Français
Español
العربية
Português
Kikongo
Dutch
kiswahili
هَوُسَ
IsiZulu
Action
Recommended articles

Report

Select your report category*



Reason*



By pressing send, your feedback will be used to improve IKCEST. Your privacy will be protected.

Submit
Cancel