Cardiovascular radiation medicine | Vol.2, Issue.4 | | Pages 241-5

Cardiovascular radiation medicine

The influence of guiding equipment and stents on the beta dose distribution in the brachytherapy of in-stent restenosis.

D, Flühs C, Wilke C, Naber M, Hienz M, Bambynek C, Kaiser I, Langner D, Baumgart W, Sauerwein D, Wegener U, Quast  
Abstract

Intracoronary devices such as stents or guide wires may disturb the dose distribution of beta sources in cardiovascular brachytherapy. As clinical observations indicate that underdosage increases the risk of restenosis, accurate measurements are mandatory to investigate these effects.Dose perturbation effects of different interventional equipment were systematically determined. Dose distributions of 90Sr-beta line sources were measured by means of a special set-up employing plastic scintillator dosimeters in a water phantom. Shielding effects were found to be 2-5% for single stents and 5-10% for graft stents, stent-in-stent geometries, and guiding catheters. Guide wires close to the source reduced the dose by 25-30%.Beta dose perturbation effects of typical stent types are almost negligible and can be corrected by an increased source dwell time if necessary. Guide wires produce effects which are clinically much more important and should therefore be retracted from the irradiation area.

Original Text (This is the original text for your reference.)

The influence of guiding equipment and stents on the beta dose distribution in the brachytherapy of in-stent restenosis.

Intracoronary devices such as stents or guide wires may disturb the dose distribution of beta sources in cardiovascular brachytherapy. As clinical observations indicate that underdosage increases the risk of restenosis, accurate measurements are mandatory to investigate these effects.Dose perturbation effects of different interventional equipment were systematically determined. Dose distributions of 90Sr-beta line sources were measured by means of a special set-up employing plastic scintillator dosimeters in a water phantom. Shielding effects were found to be 2-5% for single stents and 5-10% for graft stents, stent-in-stent geometries, and guiding catheters. Guide wires close to the source reduced the dose by 25-30%.Beta dose perturbation effects of typical stent types are almost negligible and can be corrected by an increased source dwell time if necessary. Guide wires produce effects which are clinically much more important and should therefore be retracted from the irradiation area.

+More

Cite this article
APA

APA

MLA

Chicago

D, Flühs C, Wilke C, Naber M, Hienz M, Bambynek C, Kaiser I, Langner D, Baumgart W, Sauerwein D, Wegener U, Quast,.The influence of guiding equipment and stents on the beta dose distribution in the brachytherapy of in-stent restenosis.. 2 (4),241-5.

Disclaimer: The translated content is provided by third-party translation service providers, and IKCEST shall not assume any responsibility for the accuracy and legality of the content.
Translate engine
Article's language
English
中文
Pусск
Français
Español
العربية
Português
Kikongo
Dutch
kiswahili
هَوُسَ
IsiZulu
Action
Recommended articles

Report

Select your report category*



Reason*



By pressing send, your feedback will be used to improve IKCEST. Your privacy will be protected.

Submit
Cancel