Journal of shoulder and elbow surgery / American Shoulder and Elbow Surgeons ... [et al.] | Vol.18, Issue.6 | | Pages 886-91

Journal of shoulder and elbow surgery / American Shoulder and Elbow Surgeons ... [et al.]

Optimal rotation and screw positioning for initial glenosphere baseplate fixation in reverse shoulder arthroplasty.

Bradford O, Parsons Konrad I, Gruson Kenneth J, Accousti Raymond A, Klug Evan L, Flatow  
Abstract

Critical to the longevity of the reverse shoulder arthroplasty is initial rigid fixation of the glenosphere, determined in part by baseplate screw fixation. We studied screw fixation in baseplates placed in several different orientations.Twelve, lightly-embalmed adult scapulae were implanted using a variable-angle and a fixed-angle baseplate. Baseplates were placed in three rotational positions: 1) 12/6 o'clock, 2) 20 degrees rotation toward the coracoid, and 3) 20 degrees rotation toward the scapular spine.Superiorly, perpendicular screws for the variable-angle baseplate in the 12 o'clock (39.7 mm) and coracoid (37.7 mm) position and angled screws in the coracoid position (37.5 mm) were found to be the longest. Inferiorly, screws holes made perpendicular to the baseplate yielded the longest screw lengths (37.4 mm), while inferiorly angled screws were shorter, especially in the anterior-inferior glenoid (16.8 mm).Overall, baseplate rotation toward the spine yielded the lowest mean screw lengths. Proper initial rotation of the baseplate and screw orientation can optimize initial fixation of the glenosphere in reverse shoulder arthroplasty.Level IV, Case Series, Treatment Study.

Original Text (This is the original text for your reference.)

Optimal rotation and screw positioning for initial glenosphere baseplate fixation in reverse shoulder arthroplasty.

Critical to the longevity of the reverse shoulder arthroplasty is initial rigid fixation of the glenosphere, determined in part by baseplate screw fixation. We studied screw fixation in baseplates placed in several different orientations.Twelve, lightly-embalmed adult scapulae were implanted using a variable-angle and a fixed-angle baseplate. Baseplates were placed in three rotational positions: 1) 12/6 o'clock, 2) 20 degrees rotation toward the coracoid, and 3) 20 degrees rotation toward the scapular spine.Superiorly, perpendicular screws for the variable-angle baseplate in the 12 o'clock (39.7 mm) and coracoid (37.7 mm) position and angled screws in the coracoid position (37.5 mm) were found to be the longest. Inferiorly, screws holes made perpendicular to the baseplate yielded the longest screw lengths (37.4 mm), while inferiorly angled screws were shorter, especially in the anterior-inferior glenoid (16.8 mm).Overall, baseplate rotation toward the spine yielded the lowest mean screw lengths. Proper initial rotation of the baseplate and screw orientation can optimize initial fixation of the glenosphere in reverse shoulder arthroplasty.Level IV, Case Series, Treatment Study.

+More

Cite this article
APA

APA

MLA

Chicago

Bradford O, Parsons Konrad I, Gruson Kenneth J, Accousti Raymond A, Klug Evan L, Flatow,.Optimal rotation and screw positioning for initial glenosphere baseplate fixation in reverse shoulder arthroplasty.. 18 (6),886-91.

Disclaimer: The translated content is provided by third-party translation service providers, and IKCEST shall not assume any responsibility for the accuracy and legality of the content.
Translate engine
Article's language
English
中文
Pусск
Français
Español
العربية
Português
Kikongo
Dutch
kiswahili
هَوُسَ
IsiZulu
Action
Recommended articles

Report

Select your report category*



Reason*



By pressing send, your feedback will be used to improve IKCEST. Your privacy will be protected.

Submit
Cancel