Welcome to the IKCEST

Bulletin européen de physiopathologie respiratoire | Vol.12, Issue.2 | | Pages 349-69

Bulletin européen de physiopathologie respiratoire

[Variation of effective compliance with respiratory frequency. Test of inhomogeneity of the ventilatory mechanical system (author's transl)].

G, Saumon J E, Lafosse R, Georges  
Abstract

A decrease in effective compliance (Ce) with increase in respiratory frequency (f) is considered as representing an inhomogeneity in the distribution of the pulmonary time constants. The Ce variation in relation with f reflects the inadequacy of the first order linear mono-alveolar model usually used to describe the ventilatory mechanical properties. Such an assertion is widely accepted, but few attempts have been done to validate this point in patients and to determine the various components likely to affect the Ce, f relationship. In 171 patients, selected in order to sample different types of lesions of some pulmonary structures, the authors calculated the next functional parameters : VC/theoretical VC ratio, RV by dilution method and by plethysmography, airway resistance and distribution index of inspired gas. Moreover, by means of a computerised system, the effective compliance and its variation with respiratory frequency have been calculated. After discussion of the procedure and of the method used to express the compliance-frequency relationship (linear regression), the authors develop the arguments which allow to assert that despite the elementary type of expression the relation is a good discriminative parameter. Its signification is discussed by analysing results obtained in patients and by simulating a mathematical model of the ventilatory mechanics where the mechanical parameters are distributed. It seems likely that a negative slope of the compliance-frequency relationship expresses an important mechanical inhomogeneity. Taking into account the fact that the whole frequency-compliance relationship gives little information, at this moment, in the face of an unpleasant test for the patients, the authors propose a simplified procedure, adapted to the usual practice.

Original Text (This is the original text for your reference.)

[Variation of effective compliance with respiratory frequency. Test of inhomogeneity of the ventilatory mechanical system (author's transl)].

A decrease in effective compliance (Ce) with increase in respiratory frequency (f) is considered as representing an inhomogeneity in the distribution of the pulmonary time constants. The Ce variation in relation with f reflects the inadequacy of the first order linear mono-alveolar model usually used to describe the ventilatory mechanical properties. Such an assertion is widely accepted, but few attempts have been done to validate this point in patients and to determine the various components likely to affect the Ce, f relationship. In 171 patients, selected in order to sample different types of lesions of some pulmonary structures, the authors calculated the next functional parameters : VC/theoretical VC ratio, RV by dilution method and by plethysmography, airway resistance and distribution index of inspired gas. Moreover, by means of a computerised system, the effective compliance and its variation with respiratory frequency have been calculated. After discussion of the procedure and of the method used to express the compliance-frequency relationship (linear regression), the authors develop the arguments which allow to assert that despite the elementary type of expression the relation is a good discriminative parameter. Its signification is discussed by analysing results obtained in patients and by simulating a mathematical model of the ventilatory mechanics where the mechanical parameters are distributed. It seems likely that a negative slope of the compliance-frequency relationship expresses an important mechanical inhomogeneity. Taking into account the fact that the whole frequency-compliance relationship gives little information, at this moment, in the face of an unpleasant test for the patients, the authors propose a simplified procedure, adapted to the usual practice.

+More

Cite this article
APA

APA

MLA

Chicago

G, Saumon J E, Lafosse R, Georges,.[Variation of effective compliance with respiratory frequency. Test of inhomogeneity of the ventilatory mechanical system (author's transl)].. 12 (2),349-69.

Disclaimer: The translated content is provided by third-party translation service providers, and IKCEST shall not assume any responsibility for the accuracy and legality of the content.
Translate engine
Article's language
English
中文
Pусск
Français
Español
العربية
Português
Kikongo
Dutch
kiswahili
هَوُسَ
IsiZulu
Action
Recommended articles

Report

Select your report category*



Reason*



By pressing send, your feedback will be used to improve IKCEST. Your privacy will be protected.

Submit
Cancel