Welcome to the IKCEST

In vivo (Athens, Greece) | Vol.27, Issue.6 | | Pages 851-4

In vivo (Athens, Greece)

Bioelectrical impedance analysis in pregnancy: reference ranges.

Sebastian, Berlit Benjamin, Tuschy Marlène, Stojakowits Christel, Weiss Hans, Leweling Marc, Sütterlin Sven, Kehl  
Abstract

Aim: To generate reference values for bioelectrical impedance analysis (BIA) in a German collective of healthy pregnant women.A total of 90 women with a singleton gestation from 23+0 to 40+6 weeks of pregnancy were enrolled from April 2012 until May 2013. Each week of gestation was represented by the same number of women (n=5). Mean BIA indices were generated for all patients and according to gestational age so that three collectives <30, 30 to 35 and >35 weeks of gestation were formed. Multiple regression analysis was implemented using maternal height, weight, body-mass index, gestational age, hematocrit and abdominal circumference to generate formulae to calculate individualized reference values for resistance, reactance, phase angle, height(2)/resistance, and total body water adjusted for gestation.Individualised reference values using the new formulae led to results which are more accurate than general mean values or mean values corresponding to the gestational age only.As far as we are aware of the present study is the first to report reference values for BIA indices in a German collective of healthy pregnant women. The new formulae generated by multiple regression analysis enabled for assessment of individualized reference values for BIA indices.

Original Text (This is the original text for your reference.)

Bioelectrical impedance analysis in pregnancy: reference ranges.

Aim: To generate reference values for bioelectrical impedance analysis (BIA) in a German collective of healthy pregnant women.A total of 90 women with a singleton gestation from 23+0 to 40+6 weeks of pregnancy were enrolled from April 2012 until May 2013. Each week of gestation was represented by the same number of women (n=5). Mean BIA indices were generated for all patients and according to gestational age so that three collectives <30, 30 to 35 and >35 weeks of gestation were formed. Multiple regression analysis was implemented using maternal height, weight, body-mass index, gestational age, hematocrit and abdominal circumference to generate formulae to calculate individualized reference values for resistance, reactance, phase angle, height(2)/resistance, and total body water adjusted for gestation.Individualised reference values using the new formulae led to results which are more accurate than general mean values or mean values corresponding to the gestational age only.As far as we are aware of the present study is the first to report reference values for BIA indices in a German collective of healthy pregnant women. The new formulae generated by multiple regression analysis enabled for assessment of individualized reference values for BIA indices.

+More

Cite this article
APA

APA

MLA

Chicago

Sebastian, Berlit Benjamin, Tuschy Marlène, Stojakowits Christel, Weiss Hans, Leweling Marc, Sütterlin Sven, Kehl,.Bioelectrical impedance analysis in pregnancy: reference ranges.. 27 (6),851-4.

Disclaimer: The translated content is provided by third-party translation service providers, and IKCEST shall not assume any responsibility for the accuracy and legality of the content.
Translate engine
Article's language
English
中文
Pусск
Français
Español
العربية
Português
Kikongo
Dutch
kiswahili
هَوُسَ
IsiZulu
Action
Recommended articles

Report

Select your report category*



Reason*



By pressing send, your feedback will be used to improve IKCEST. Your privacy will be protected.

Submit
Cancel