Indoor and outdoor measurements of particle number concentration in near-highway homes.

Christina H, Fuller Doug, Brugge Paige L, Williams Murray A, Mittleman Kevin, Lane John L, Durant John D, Spengler  
Abstract

Exposure to high levels of traffic-generated particles may pose risks to human health; however, limited measurement has been conducted at homes near highways. The purpose of this study was to characterize differences between indoor and outdoor particle number concentration (PNC) in homes near to and distant from a highway and to identify factors that may affect infiltration. We monitored indoor and outdoor PNC (6-3000 nm) for 1-3 weeks at 18 homes located <1500 m from Interstate-93 (I-93) in Somerville, MA (USA). Median hourly indoor and outdoor PNC pooled over all homes were 5.2 × 10(3) and 5.9 × 10(3) particles/cm(3), respectively; the median ratio of indoor-to-outdoor PNC was 0.95 (5(th)/95th percentile: 0.42/1.75). Homes <100 m from I-93 (n=4) had higher indoor and outdoor PNC compared with homes >1000 m away (n=3). In regression models, a 10% increase in outdoor PNC was associated with an approximately equal (10.8%) increase in indoor PNC. Wind speed and direction, temperature, time of day and weekday were also associated with indoor PNC. Average mean indoor PNC was lower for homes with air conditioners compared with homes without air conditioning. These results may have significance for estimating indoor, personal exposures to traffic-related air pollution.

Original Text (This is the original text for your reference.)

Indoor and outdoor measurements of particle number concentration in near-highway homes.

Exposure to high levels of traffic-generated particles may pose risks to human health; however, limited measurement has been conducted at homes near highways. The purpose of this study was to characterize differences between indoor and outdoor particle number concentration (PNC) in homes near to and distant from a highway and to identify factors that may affect infiltration. We monitored indoor and outdoor PNC (6-3000 nm) for 1-3 weeks at 18 homes located <1500 m from Interstate-93 (I-93) in Somerville, MA (USA). Median hourly indoor and outdoor PNC pooled over all homes were 5.2 × 10(3) and 5.9 × 10(3) particles/cm(3), respectively; the median ratio of indoor-to-outdoor PNC was 0.95 (5(th)/95th percentile: 0.42/1.75). Homes <100 m from I-93 (n=4) had higher indoor and outdoor PNC compared with homes >1000 m away (n=3). In regression models, a 10% increase in outdoor PNC was associated with an approximately equal (10.8%) increase in indoor PNC. Wind speed and direction, temperature, time of day and weekday were also associated with indoor PNC. Average mean indoor PNC was lower for homes with air conditioners compared with homes without air conditioning. These results may have significance for estimating indoor, personal exposures to traffic-related air pollution.

+More

Cite this article
APA

APA

MLA

Chicago

Christina H, Fuller Doug, Brugge Paige L, Williams Murray A, Mittleman Kevin, Lane John L, Durant John D, Spengler,.Indoor and outdoor measurements of particle number concentration in near-highway homes.. 23 (5),506-12.

Disclaimer: The translated content is provided by third-party translation service providers, and IKCEST shall not assume any responsibility for the accuracy and legality of the content.
Translate engine
Article's language
English
中文
Pусск
Français
Español
العربية
Português
Kikongo
Dutch
kiswahili
هَوُسَ
IsiZulu
Action
Recommended articles

Report

Select your report category*



Reason*



By pressing send, your feedback will be used to improve IKCEST. Your privacy will be protected.

Submit
Cancel