Welcome to the IKCEST

Composite Structures | Vol.201, Issue.0 | | Pages

Composite Structures

Post-fire residual properties of GFRP reinforced concrete slabs: A holistic investigation

Hamzeh Hajiloo   Mark F. Green  
Abstract

This paper provides critical data regarding the post-fire residual strength of Glass Fibre Reinforced Polymer (GFRP) reinforced concrete slabs. The residual tensile and bond strength of three types of GFRP reinforcing bars and the post-fire residual strength of a GFRP reinforced concrete slab are examined. For residual tensile strength, GFRP bars with a nominal diameter of 16 mm are exposed to temperatures up to 450 °C and tested after 24 h at room temperature. After 24 h, the specimens are loaded to failure at room temperature. For residual bond strength, pullout specimens are heated under various sustained load values. Finally, a full-scale GFRP reinforced concrete slab is tested at room temperature to evaluate the post-fire residual capacity after exposure to three hours of a standard fire. The residual tensile test results show that the bars that were exposed to 400 °C recovered at least 45% of the original strength while the residual bond strength is approximately 40% for pullout specimens that had experienced 300 °C. The post-fire residual strength of the slab is 68% of its room temperature flexural design strength with the bond loss at the ends of the slab being the governing mode of failure.

Original Text (This is the original text for your reference.)

Post-fire residual properties of GFRP reinforced concrete slabs: A holistic investigation

This paper provides critical data regarding the post-fire residual strength of Glass Fibre Reinforced Polymer (GFRP) reinforced concrete slabs. The residual tensile and bond strength of three types of GFRP reinforcing bars and the post-fire residual strength of a GFRP reinforced concrete slab are examined. For residual tensile strength, GFRP bars with a nominal diameter of 16 mm are exposed to temperatures up to 450 °C and tested after 24 h at room temperature. After 24 h, the specimens are loaded to failure at room temperature. For residual bond strength, pullout specimens are heated under various sustained load values. Finally, a full-scale GFRP reinforced concrete slab is tested at room temperature to evaluate the post-fire residual capacity after exposure to three hours of a standard fire. The residual tensile test results show that the bars that were exposed to 400 °C recovered at least 45% of the original strength while the residual bond strength is approximately 40% for pullout specimens that had experienced 300 °C. The post-fire residual strength of the slab is 68% of its room temperature flexural design strength with the bond loss at the ends of the slab being the governing mode of failure.

+More

Cite this article
APA

APA

MLA

Chicago

Hamzeh Hajiloo, Mark F. Green,.Post-fire residual properties of GFRP reinforced concrete slabs: A holistic investigation. 201 (0),.

Disclaimer: The translated content is provided by third-party translation service providers, and IKCEST shall not assume any responsibility for the accuracy and legality of the content.
Translate engine
Article's language
English
中文
Pусск
Français
Español
العربية
Português
Kikongo
Dutch
kiswahili
هَوُسَ
IsiZulu
Action
Recommended articles

Report

Select your report category*



Reason*



By pressing send, your feedback will be used to improve IKCEST. Your privacy will be protected.

Submit
Cancel